Precautions before starting and operation of
magnetic pump:
A remove the dirt around the machine and equipment that
endangers the safety of the machine and equipment and the actual operating
staff.
B before driving, fill the pump with the liquid to be transported (if
the pump is sucking), open the inlet valve, close the outlet stop valve, and
connect the power supply.
C. connect the power supply and check whether the
rotation direction of the pump is appropriate.
D. the generator set shall be
put into trial operation for 3-6 minutes. If there is no abnormal condition,
funds can be put into operation.
F when starting up for the first time after
long-term shutdown or pump maintenance, remove the cooling fan cover of the
motor and manually switch it off, check whether the magnetic pump rotates
flexibly, and install the cooling fan cover after confirming that there is no
problem.
2. Normal shutdown of magnetic pump
First turn off the stop valve
at the outlet, and then turn off the power supply.
3. Emergency
braking
Stop the motor immediately, and then close the outlet valve and inlet
valve.
4. Overhaul and maintenance of magnetic pump
Regularly maintain the
pump and motor, and replace vulnerable parts.
When it is unnecessary to shut
down for a long time, clean the flow passage in the pump with high pressure and
disconnect the power supply.
No idling.
5. Common problems in the
operation of magnetic pump
A pay attention to the pressure difference between
the front, back, left and right of the suction end filter device. When the
pressure difference rises, it means that the filter device is blocked by dirt,
and the pump operation should be stopped to facilitate the cleaning of the
coarse filter.
B. whether the discharge volume and working pressure meet the
standard value; C. whether there is abnormal sound and vibration. If there is
abnormal sound or vibration, it generally indicates cavitation or excessive
bearing damage.
E. whether the pump produces cavitation: open the outlet gate
valve of the pump. When the total flow reaches a certain amount, suddenly there
is sound and vibration. At this time, amplify the gate valve again. If the total
flow still does not increase, it indicates cavitation. In case of cavitation,
the actual operation of exhaust pipe shall be carried out. Note: the magnetic
pump must not run under cavitation conditions. If it runs again under such
conditions, it will cause initial damage to the bearing.
F whether the
current of the motor exceeds the rated voltage.
G. whether the temperature at
each position of the pump is abnormally overheated.
H the working pressure of
nitrogen pressure stabilization system shall be maintained within the required
range.
7/31/2022
Maintenance of magnetic pump
7/28/2022
Function of centrifugal pump press out chamber
37. What is the function of
centrifugal pump? How many forms of DP?
Answer: the function of screw pump
press out chamber is to correctly guide the liquid with minimum loss
The next
stage impeller may be led to the outlet pipe, and part of the kinetic energy is
converted into pressure energy at the same time.
There are three common types
of diaphragm pump press out chamber:
(1) Spiral volute is used to collect
liquid gear pump. Kinetic energy becomes pressure energy
It is carried out in
the diffuser.
(2) Radial guide vane, which is fixed outside the impeller
outlet
The role of.
(3) Ring type press out chamber, used on segmented
multi-stage pump*
38. What is the texture color given by centrifugal spring
leaves 7
Answer: the impeller of centrifugal pump is generally made of metal,
which enters according to the liquid flow
It can be divided into single
suction PR force and double suction impeller, which are mainly composed of blade
and wheel
The two-part 6-wheel is used to fix the blade and fix the calling
wheel on the pump shaft-l.
39. What is the function of centrifugal spring
coupling 7
Answer: the function of centrifugal pump coupling is to connect
the pump shaft with the prime mover shaft
Play a role in transmitting the
energy of the prime mover, buffering axial and radial vibrations,
and
Automatically adjust the operation of the prime mover and the slave
machine.
40. How many LP couplers are used?
Answer: there are three
commonly used couplings:
(1) Rigid coupling, suitable for small, low-speed
words with little vibration
On each;
(2) Elastic coupling is suitable for
high-speed equipment with variable load,
(3) Gear couplings are mostly used
on low-speed heavy equipment.
electric high vacuum butterfly valve of three factors should be considered in the selection
7/26/2022
Daily maintenance of high temperature heat transfer oil pump
1. Shutdown:
cut off the power supply. Empty the liquid in the heat transfer oil pump, clean
it, and rotate the impeller 180 degrees regularly to prevent shaft deformation
until the oil pump cools down.
2. The heat transfer oil pump uses fuel with
appropriate grade. Generally, No.0 diesel oil is used in summer and No.10 light
diesel oil is used in winter.
3. The fuel used by the heat transfer oil pump
shall be clean and free of any impurities and moisture. 4. It is normal to have
a small amount of leakage at the beginning of the operation of the heat transfer
oil pump. After time, the leakage will be reduced or stopped after the sealing
surface runs in. Because the heat transfer oil pump shaft is equipped with a
stuffing box at the front end, the sealing performance is relatively good, and
at the same time, a mechanical sealing device is set in the bearing seat, so a
large amount of leakage is impossible to occur, and a small amount of leakage
can be discharged and received through the leakage pipe orifice.
5. The heat
transferred from the transmission medium to the pump cover and bearing of the
heat transfer oil pump is dissipated by the surface of the pump cover and
bearing seat, so that the temperature of the bearing seat can adapt to the
temperature of the shaft sealing performance. Therefore, when selecting the
installation position of the heat transfer oil pump, the heat of the pump cover
and bearing seat should be easy to diffuse without any heat storage.
6. Two
ball bearings are set in the bearing seat. A ball bearing on the pump impeller
side of the heat transfer oil pump is lubricated with the transmitted heat
transfer oil, and a ball bearing on the coupling side is lubricated with
high-temperature grease: after 3000 hours of operation, each ball bearing is
removed and cleaned with diesel oil, and the contact surface is checked for
damage. If it is damaged, replace it with a new bearing. When installing the
ball bearing near the impeller side, the side with dust cover should be
installed towards the impeller, and heat transfer oil should be injected for
lubrication before startup. The ball bearing near the coupling side is
lubricated with compound calcium base high temperature grease. When the bearing
is reinstalled, the side with dust cover should also be installed towards the
impeller side, and the grease should be filled during installation. After the
bearing runs for 48 hours, use a grease gun to inject supplementary grease into
the pressure injection cup on the bearing cover.
vacuum pump manufacturers to repair cracks by measures taken
Chemical pump maintenance can be divided into several categories!
In the
chemical industry, petrochemical industry, and many other industries, chemical
pumps, centrifugal pumps, magnetic pumps and other equipment are repaired in
order to restore their functions after deterioration or failure, including all
kinds of planned maintenance and unscheduled fault maintenance and other
maintenance. The basic contents of pump equipment maintenance include: equipment
maintenance, equipment inspection, equipment repair and replacement.
Pump
maintenance type
Post accident maintenance
In the maintenance strategy
after the equipment works to the occurrence of obvious faults, the measures
taken are to dismantle the damaged equipment or components for repair or
renewal.
characteristic:
① The cost of maintenance is high and a waste of
time, delaying normal production.
② Reserve various spare parts for
replacement; Allocate more maintenance workers to deal with
maintenance.
Regular preventive maintenance
Go to the site for maintenance
according to the predetermined time interval, and repair or replace the
equipment before major faults occur.
characteristic:
① The maintenance
cost is less than that after the accident.
② Improper maintenance interval
will cause unnecessary excessive maintenance.
Condition monitoring and
maintenance
Based on the actual working condition of the equipment, it is
implemented through the monitoring results of the equipment.
Whether to
repair depends on abnormal phenomena such as mechanical vibration, bearing
temperature and running noise.
If a selected parameter reaches the
predetermined critical value, the equipment will be shut down for maintenance,
so as to avoid more serious accidents.
characteristic:
① The maintenance
goal is clear and the production efficiency is high.
② It is necessary to
purchase corresponding testing equipment and train personnel.
Standard
preventive maintenance procedures
Daily inspection work content
① Check
whether the discharge pressure of the pump is normal.
② Check the sound,
vibration and bearing temperature when the pump is running.
③ Check the pump
body and auxiliary pipelines for leakage.
④ Check whether the coupling guard
is loose.
⑤ Check the amount of lubricating oil and sealing cooling
water.
⑥ Keep the equipment clean.
⑦ If any abnormality is found, report
to the dispatcher.
2BE1-355 pump for bearing and mechanical seal of disassembling process
7/24/2022
What is a shaft seal free centrifugal pump?
1、 Overview of shaft seal free
centrifugal pump
Shaft seal free centrifugal pump is also known as packing
free centrifugal pump. It is usually a vertical canned motor or a horizontal
canned motor, which is driven by a wet winding motor without a shielding
pad.
In this case, the pump and motor share a pressure pump housing, and
there is a heat shield between the pump parts and the motor parts. The heat
shield can be active or passive. The allowable medium temperature is as high as
420 ℃
2、 Characteristics of shaft seal free centrifugal pump
The bearing
is lubricated by discharging medium. In practice, there is no limit to the
system pressure, because the total leakage rate is slightly higher than the
mark, so it can be used for dangerous media or valuable media.
3、 Special
form of shaft seal free centrifugal pump
The special form of shaft seal free
centrifugal pump is designed according to the application purpose.
·Special
impellers for liquid and gas mixtures or suspended solids
·Sealing system
specially used for nuclear reactor technology or sealing system with protective
gas gasket
·Heating device specially used for quick condensing fluid, such as
hot water circulating pump
·Protective cover with abrasion protection
7/22/2022
Large flow portable submersible pump
Maintenance method of large flow
portable flood control and rescue submersible pump
Maintenance methods of
portable submersible pumps, flood control submersible pumps, and large flow
portable submersible pumps
Due to the high purchase cost of the large flow
portable submersible pump, it is necessary to carry out regular maintenance
before the damage of the large flow portable submersible pump is found in the
process of use. Here are the maintenance methods of the large flow portable
submersible pump for your reference:
Easily damaged parts: mechanical
seal
Portable submersible pump oil chamber
The way to check in advance is
to loosen the screw and check whether the oil level inside is full. If there is
no oil inside, it is likely that an oil seal at the bottom is broken. If the oil
seal is broken, it is recommended to return to the factory for maintenance and
replacement. If there is still oil inside, please turn the pump upside down to
let the oil inside out into a container and observe whether the oil contains
water, If there is water in the oil, it means that the waterproof mechanical
seal needs to be replaced.
The method to replace the waterproof mechanical
seal is as follows: first remove the fixing screws at the water outlet of the
submersible pump and remove the water outlet, then remove the impeller screws,
find a rectangular wood, put one end on the bottom of the impeller, and use a
hammer to knock down the upper end of the square wood with a hammer to lift the
impeller down, and then remove the three bolts of the oil chamber cover plate
and remove the cover plate to see the relevant parts of the mechanical seal,
Before removing the mechanical seal, remember the installation sequence of the
mechanical seal. It is recommended to take photos and archive them. After
removing the old mechanical seal, install the new mechanical seal in the correct
sequence, and then install the cover plate of the oil chamber according to the
removal sequence, fill the oil chamber with transformer oil, and then install
the impeller and water outlet.
Large flow portable submersible pump
To
learn more about large flow portable submersible pump, recommended reading:
Portable submersible pump
If you want to choose a self-priming pump and
configure it on the power pump truck, it is recommended to read: large flow
self-priming pump
If the delivered liquid contains a lot of impurities, it is
recommended to choose stainless steel submersible pump for sewage
7/20/2022
Does the self-priming pump need to install a bottom valve?
The common
self-priming pump refers to the external mixing suction and filtration
self-priming pump. According to the rotation of the centrifugal impeller, the
liquid flows into the volute, and then the pump shell generates a vacuum pump.
In that way, the product of the self-priming pump will start, suck the liquid in
from the inlet, and transport the liquid out according to the path of the
impeller. It is the principle of the self-priming pump.
An obvious feature of
self-priming pump different from centrifugal pump is that it does not need to
inject water in the case of application. However, in the case of a single
application, you must remember to inject water into the pump cavity. Because the
pump shell itself does not store liquid, if you do not inject water in the case
of a single application, the pump will rotate at a high speed, which will not
only prevent the liquid from being sucked up, but also continue to burn the
mechanical seal and other parts of the pump shell due to the high rotation
speed. Therefore, you must pay attention to this.
So should the self-priming
pump be installed with a bottom valve
01
If the bottom valve is not
installed
What is the situation?
Generally speaking, there is no need to
install the bottom valve. Generally, the inlet of the self-priming pump is
equipped with a check valve, which is often referred to as this product, so
after the pump is terminated, the liquid in the pump body cannot flow back to
the original pool and be stored in the pump body, so there is no need to add
liquid in the case of the second application,
02
If the bottom valve is
installed
What about the situation?
If the bottom valve is refitted, the
actual effect will be better, because sometimes if this product is destroyed,
there is also a bottom valve as a guarantee, which is not easy to appear high
speed, and after refitting the bottom valve, it will also reasonably ensure the
reasonable suction lift of the pump!
Another special case, but if there is
too much difference in the suction height width ratio, or the suction pipe is
large, and the volume exceeds the liquid storage in the self-priming pump
cavity, everything cannot work normally. At this time, it is necessary to refit
the bottom valve to ensure the rapid safety of natural suction.