(1) Improve the system planning of plunger pump. After repeated verification,
the leading priority valve and load sensing full plunger steering system are
finally selected. Regardless of the size of the load and the uneven speed of the
steering wheel, the new system can distribute the flow according to the steering
demand. You can use some equipment to supply oil to the operating equipment
circuit, then eliminate the power loss caused by too much oil supply to the
steering circuit, increase the system power, and reduce the working pressure of
the plunger pump.
(2) Optimize the appearance of the boom cylinders and the
plunger pumps to reduce the operating pressure of the system. After optimization
calculation, select boom cylinder from standard series 80 / 4. The displacement
of the plunger pump is increased from 10ml / R to 14ml / R, and the set pressure
of the system is 14MPa, which meets the lifting force and speed requirements of
the boom cylinder.
(3) During the operation, pay attention to the correct use
and protection of the loader, add or replace the hydraulic oil regularly, keep
the cleanliness of the oil, and strengthen the regular observation and
protection.
Technical parameters:
1. Work positioning 12 stations,
two stations synchronous welding;
2. IGBT transistor high frequency power
supply 2x25kw, working frequency 25 ± 5KHz;
3. Input voltage 380V, frequency
50 (60) Hz;
4. Water cooling system: water pressure 2-3kgf / cm2, input water
temperature < 30 ℃, water flow 30L / min;
5. Automatic switch to two-stage
heating mode;
6. Operation mode: automatic program control / manual
control;
7. Overall dimension: 1875x1680x1680.