Generally
speaking, the water ring vacuum pump in normal operation will not have any
problems, but this is not allowed. Sometimes, the pump in normal operation will
suddenly stop running, and this situation is not caused for no reason. There are
still many reasons:
1. The power failure may also be the reason why the water
ring vacuum pump suddenly does not run. First check its power supply to see if
it is powered off, eliminate the fault in time and restore the power
supply.
2. The reason why the water ring vacuum pump suddenly does not run
may be that the control protection switch of the vacuum pump trips. The main
reason for the control protection switch tripping is that the vacuum pump is
damaged during operation or due to overload of the vacuum pump motor. The
treatment method for the sudden non rotation of the vacuum pump is to measure
the insulation resistance of the vacuum pump motor first, and check whether the
stator winding of the vacuum pump motor is damaged and whether other parts are
damaged.
3. The broken core wire of the power supply cable of the water ring
vacuum pump may also be the reason for the sudden non rotation of the vacuum
pump. The treatment method for the sudden non rotation of the vacuum pump is to
connect the broken core wire of the motor power supply cable and wrap it with
insulating tape. If the connection repaired after the power supply cable is
broken needs to be immersed in water, the cable shall be treated or replaced
according to the waterproof connection and sealing requirements of the cable
joint.
4. The action of the thermal protector of the water ring vacuum pump
may also be the reason for the sudden non rotation of the vacuum pump: the main
reason for the action of the thermal protector of the vacuum pump is the
overload of the vacuum pump or the poor heat dissipation or dehydration
operation of the vacuum pump motor; Or it is caused by malfunction of thermal
protector. The treatment method is to check the cause of the action of the
thermal protector and eliminate it, waiting for its automatic reset or repair
and adjustment.
5. The stator winding of the water ring vacuum pump is burnt
out, which may also be the cause of the sudden non rotation of the vacuum pump.
If it is found that the stator winding of the vacuum pump is burnt out, first
check the cause of the damage of the stator winding and eliminate the fault to
prevent the motor stator winding from being damaged again; Then disassemble and
repair the motor stator winding and replace the damaged stator winding as
required.
7. There may also be the reason why the motor is burnt out due to
water ingress caused by medium corrosion. The liquid is corrosive. It is
recommended to use stainless steel.
Therefore, once the water ring vacuum
pump used by everyone has such a situation, what to do is always careful and
careful inspection. The inspection results determine which way we will choose to
deal with it, so that we can continue to use the vacuum pump.