3/29/2023

Common faults and treatment of mixed flow pump

 

In practice, troubleshooting should be based on specific problems and actual analysis. The principle of "outside first, then inside" should be followed, and blind operation is not allowed.
First of all, it is necessary to inspect the power supply: whether the connectors are firmly connected; Whether the switch contact is meticulous; Whether the fuse is blown; Whether the three-phase power supply lacks equality. If there is an open circuit, poor contact, blown fuse, or lack of phase, the cause should be identified and repaired in a timely manner. Secondly, check whether it is a mechanical fault of the water pump itself.
Symptom 1: The water pump cannot be started
Common causes: packing is too tight or the impeller and pump body are blocked by debris accumulation; The pump shaft, bearing, and leakage reduction ring are rusted; The pump shaft is severely bent, etc.
Troubleshooting: Loosen the filler and dredge the water diversion channel; Disassemble the pump body to remove debris and rust; Remove the pump shaft for correction or replace with a new pump shaft.

Vacuum Pump: Difference Between Oil Type And Oil Free Type 