1. air leakage of centrifugal pump or suction pipe;
2. the
suction pipeline or centrifugal pump inlet is blocked, and the suction
resistance is too large;
3. the wear clearance of impeller ring is too
large;
4. the impeller is blocked or severely worn and corroded;
5. the
rotation direction of the centrifugal pump is wrong or the impeller is installed
reversely;
6. the outlet valve of the centrifugal pump is not opened or
cannot be opened;
7. the motor speed is not allowed;
8. the selection or
function of centrifugal pump is inconsistent.
Treatment method:
1. check
and clean the suction valve and pipeline;
2. remove impeller blockage or
replace impeller;
3. replace the impeller sealing ring;
4. check and
eliminate air leakage;
5. open the outlet valve of the pump and adjust the
valve opening;
6. adjust the rotation direction of the pump;
7. increase
the motor speed;
8. check whether the functional parameters of the pump meet
the working conditions and adjust them.