The anti leakage magnetic pump is applicable to the pumping and
circulation of all clean chemical solutions containing acid and alkali
components. It is widely used in electroplating, electronics, chemical industry,
leather, dyeing and finishing wastewater, and can be used with electroplating
filters. What are the characteristics of leakage proof magnetic pumps and how
should they be operated?
Features of leakage proof magnetic pump:
• adopt
magnetic drive, no shaft seal design, and the pump body is completely
sealed.
• FRPP and PVDF materials are used for injection molding, which is
suitable for most chemical acid-base liquid transportation.
• impeller and
magnet are integrally injection molded, which is not easy to be damaged under
high-speed operation and high temperature.
• due to its innovative anti
idling design, this pump series is a magnetic pump that operates without water
for a long time without damage, thus improving the durability of the
product.
• the pump bearing is made of silicon carbide, ceramic and titanium
metal, which can meet the needs of different workplaces.
Operating
instructions for leakage proof magnetic pump:
1. Confirm the direction during
the test run. If the direction is wrong, restart the motor after the motor is
completely stopped.
2. If the coupling magnet is demagnetized, please stop
the pump within one minute. If the demagnetized state continues to operate, the
coupling force of the magnet will be reduced.
3. Please limit the liquid
temperature change during startup, shutdown and operation to within 80 ℃.
5.
Close the outlet valve during startup. However, it is not allowed to operate for
a long time when the outlet valve is closed, and the internal temperature rise
will damage the pump.
5. In case of power failure during operation, please
cut off the power supply immediately and close the outlet valve.
6. Please
observe the following items before starting the operation and after long-term
shutdown:
① Clean the inside of the pipeline and the tank before supplying
water.
② Please lock the flange interface bolts and foundation bolts.
③
Rotate the motor fan with a screwdriver to check whether it rotates
smoothly.
④ After the startup water is poured into the pump, please
completely close the outlet valve.
⑤. When the suction condition is press in,
first confirm the pressure in the pipeline and then confirm whether the pump is
filled with liquid. Rotate the motor fan with a driver to rotate the pump, and
discharge the air remaining in the impeller from the exhaust port on the
pipeline.
⑥. When the upper suction type is used, the starting water is
poured into the pump while the motor fan is rotated with a driver to rotate the
pump, and the air remaining in the impeller is discharged from the exhaust port
on the pipeline.
⑦. After starting, confirm whether the rotation direction of
the motor is correct. The rotation direction shall follow the arrow indication
of the pump mark. Please change the wiring when returning in the reverse
direction.
7. The pump starts to operate normally. When the pressure gauge
reaches the higher pressure of the pump, slowly open the outlet valve until the
pressure gauge shows the discharge pressure to be set.
8. The operation time
when the outlet valve is closed shall be controlled within 1 minute.
9. When
the pump is running continuously, please use the flowmeter to confirm whether
the pump is running at the appropriate operating point.
10. When the pump is
to be stopped in cold weather, the pump may be damaged due to the freezing of
the liquid inside the pump. Please discharge the liquid inside the pump after
stopping. If the operation is interrupted only for a time and the internal
liquid cannot be discharged, please keep the pump warm with a heater to prevent
the internal liquid from freezing.