Pipeline pump can send water out
because of centrifugal force. Before the pump works, the pump body and the inlet
pipe must be filled with water to form a vacuum state. When the impeller rotates
rapidly, the blades promote the water to rotate quickly. The rotating water
flies away from the impeller under the action of centrifugal force. After the
water in the pump is thrown out, the central part of the impeller forms a vacuum
region. Under the action of atmospheric pressure (or water pressure), the water
of Shuiyuan is pressed into the inlet pipe through the pipe network. In this
way, continuous pumping can be realized. It is worth mentioning here that the
centrifugal pump can be started only after the pump shell is filled with water
before starting, otherwise, the pump body will be heated, vibrated, the water
output will be reduced, the pump will be damaged (referred to as "cavitation")
and the equipment accident will be caused!
There are many types of pipeline
pumps. The common classification methods are as follows
According to the
impeller suction mode, it is divided into single suction pipeline pump and
double suction pipeline pump.
According to the number of impellers:
single-stage pipeline pump and multi-stage centrifugal pump.
According to the
impeller structure, it is divided into open impeller pipeline pump, semi open
impeller pipeline pump and closed impeller pipeline pump.
According to the
working pressure, it is divided into low-pressure pipeline pump, medium pressure
pipeline pump, high-pressure pipeline pump and vertical pipeline pump.
Five
key points for use of pipeline pump:
Test run: check whether the connecting
parts are loose; Turn the coupling manually to rotate the rotor for several
turns, and check whether the unit rotates flexibly, whether there is sound and
uneven weight, so as to judge whether there is foreign matter in the pump or
whether the shaft is bent, whether the seal is installed correctly, etc; Check
whether the clean No. 20 lubricating oil in the sealing cavity is filled with 1
/ 2 of the cavity space; Whether the surface of the pump unit is clean; Unit
steering no-load test.
Manual start: fill the pump (for the first time),
slightly open the outlet valve and start the motor. When the pressure rises and
it is confirmed that the pump unit operates stably, gradually open the outlet
valve to the working condition.
Operation inspection: when the pump operates
normally at power frequency (frequency conversion), the readings of ammeter,
voltmeter, inlet and outlet vacuum gauge, pressure gauge and flowmeter of the
pump unit shall be regularly checked and recorded. Whether the vibration, noise
and temperature rise of the unit are normal. There shall be no obvious aviation
oil leakage at the shaft seal.
Normal shutdown: close the discharge valve to
make the pump light load and stop the motor.
Emergency stop condition:
The
indication of pump motor working ammeter is abnormal (too large or too few); The
pump system makes abnormal noise.
The vacuum pressure gauge at the inlet and
outlet of the pump indicate abnormally, the pump body vibrates greatly and makes
abnormal noise, and the performance is seriously degraded.
The pump motor
produces odor, aviation oil leaks from the shaft seal, and the bearing
temperature exceeds 75 degrees.