Water ring vacuum pump leakage response measures


Water ring vacuum pump in the use of the process such as found leakage should first distinguish is: leakage of the parts of the vacuum pump or pipeline, because the two are taken to solve the Russian measures are different.
1. Method of detecting water ring vacuum pump: separate the vacuum pump from its pipeline and directly measure the air inlet of the vacuum pump with a vacuum gauge.
2. Method of pipeline detection: remove the pipeline or a section of the pipeline, connect one end of the pipeline to the pump with no leakage, and measure the other end with a vacuum meter, through which the point of leakage can be distinguished.
At present main products are vacuum pump manufacturer bv5, 2 bv6, 2 be1, 2 be3, SK, 2 SK series water ring vacuum pump/gas drainage pump, 2 bw closed-circuit circulation system, JZJ2B, JZJ2S series liquid ring, JZJVV roots - water ring vacuum unit series and special ZF series vacuum negative pressure oxygen to hospital center station, Siemens vacuum pump, mainly used in chemical, petrochemical, light industry, pharmaceutical, paper making, metallurgy, building materials, electrical appliances, food, coal washing, processing, fertilizer and other industries, in many of the industrial production process, such as: Vacuum filter, vacuum water diversion, vacuum feeding, vacuum evaporation, vacuum concentration, vacuum resurgence and vacuum degassing is widely used, because the water ring pump in the gas compression is isothermal, therefore, can smoke in addition to flammable and explosive gases (explosion-proof motor) can also take in addition to the dust, water, gas, when the pump body material to be able to bear or endure corrupt, can also pump is corrosive gases.

Remanufactured Liquid Ring Vacuum Pumps
Remanufactured Nash* CL Series Pumps
Hanoi 26th international medical

No comments:

Post a Comment