Common faults and treatment of corrosion-resistant vertical pump:
1. The
bearing assembly is unreasonable. Reassemble the bearing and shaft, or replace
the bearing.
2. The motor shaft and pump shaft are asymmetric or not
parallel. Should adjust the motor shaft or pump shaft, if the shaft deformation
or bending directly replace the shaft.
3. There is friction in the pump or
the impeller is out of balance. The friction should be eliminated or the
impeller should be replaced.
4. The pump cavitation is caused by the
mismatching of pipe pump characteristics. The pump characteristics should be
adjusted to match the pipe characteristics.
5. The local air tightness is
eliminated by adding an exhaust valve at the air tightness.
6. If the shaft
sleeve is seriously worn, replace it with a new one
7. The elastic pad of the
coupling is damaged. Replace it with a new one
Corrosion resistant vertical
pump maintenance should pay attention to the following:
1) The water pressure
and water quantity of the bearing should meet the requirements, and the
tightness of the packing should be adjusted (or replaced) at any time to avoid
slurry leakage of the shaft seal. And replace the shaft sleeve in time.
2)
When replacing the bearing, make sure that there is no dust in the bearing
assembly and the lubricating oil is clean. When the corrosion-resistant vertical
pump is running, the bearing temperature is generally 60-650 degrees, and the
maximum temperature is not more than 750 degrees.
3) To ensure the coaxiality
of the motor and pump, ensure the integrity and correctness of the elastic pad
in the coupling, and replace it in time after damage.
4) Ensure that the pump
components and piping system are installed correctly, firmly and reliably.
5)
Some parts of vertical pump are vulnerable parts. In daily use, we should pay
attention to the loss of vulnerable parts and repair or replace them in time. In
the process of repairing or replacing the vulnerable parts of
corrosion-resistant vertical pump, it is necessary to ensure the correct
assembly, reasonable gap adjustment and avoid the occurrence of tight
friction.
6) The suction pipeline system of vertical pump must be free of air
leakage, and attention should be paid to whether the suction inlet is blocked
during operation.