Centrifugal pump
test method and precautions for centrifugal pump test
The installation of
centrifugal pump should be completed in advance according to the following items
when the centrifugal pump and centrifugal pump are installed
1. Before
starting the centrifugal pump, it is forbidden to run the pump with no-load and
no-load. The test run with liquid shall be carried out according to the
operating procedures specified above in the operating instructions of the
centrifugal pump. For the forced lubrication system, the temperature rise of the
bearing oil of the centrifugal pump shall not exceed 28 ° C and the temperature
of the bearing metal shall be less than 93 ° C.
2. For centrifugal pumps with
oil ring lubrication or splash lubrication system, the temperature of
lubricating oil shall not exceed 39 degrees, and the temperature of bearing
parts shall be less than 82 degrees.
3. When testing the centrifugal pump,
the vibration value of the bearing of the centrifugal pump should also be
checked. The vibration standard of the bearing of the centrifugal pump can refer
to the vibration standard of relevant Petrochemical rotating machinery.
4.
During the test run of the centrifugal pump, the operation of the centrifugal
pump should be very balanced and noise free, the coolant and lubricating oil
system should be normal, and the centrifugal pump and auxiliary pipelines should
be free of leakage.
5. During the commissioning of the centrifugal pump, it
should be noted whether the current of the centrifugal pump motor operates
within the specified range. If the overcurrent indicates that the actual working
condition head is lower than the pump head, it is recommended to turn down the
outlet valve to control the flow of the centrifugal pump so that its current can
be used within the rated current range.
6. The leakage of various seals and
media of centrifugal pump shall not exceed the requirements of the following
standards:
(1) Clean water centrifugal pump with mechanical seal: light oil
10 drops / min, heavy oil 5 drops / min
(2) Multistage centrifugal pump with
packing seal: light oil 20 drops / min, heavy oil 10 drops / min
(3) For the
magnetic drive pump conveying toxic, harmful, flammable and explosive media, no
obvious leakage is allowed.
2/16/2022
Centrifugal pump commissioning method and precautions
Subscribe to:
Post Comments (Atom)
No comments:
Post a Comment