The self-priming pump manual
attached by many manufacturers basically introduces the self-priming pump model
performance parameters, self-priming pump characteristics and scope of use, and
the self-priming pump installation dimensions, but there is no specific
self-priming pump instructions, * which can not meet the standards of
self-priming pump manual, so it is necessary to share knowledge about
self-priming pump instructions for users for reference, After the self-priming
pump unit is installed and adjusted (refer to the installation of self-priming
pump for installation knowledge), water can be added for trial operation.
1.
Start
(1) Before starting, check whether the self-priming pump has friction
and whether it can rotate flexibly. It is prohibited to start the self-priming
pump when there is friction.
(2) For the self-priming pump with suspension
oil chamber, check the oil level in the suspension oil chamber to see if it is
within the specified range.
(3) Open the inlet valve *; Open the water
injection valve to inject water into the pump to discharge the gas in the
self-priming pump.
(4) Close the outlet valve and pressure gauge cock.
(5)
After the above steps are completed, start the motor and open the pressure gauge
cock to see whether the pressure gauge pointer is at the correct
position.
(6) Open the vacuum gauge cock and slowly open the water outlet
valve. At this time, the position of the pressure gauge pointer will change with
the opening degree of the water outlet valve. Stop adjusting the size of the
outlet valve when the pointer of the pressure gauge points to the required
position under the working condition.
Note: Starting the self-priming pump
when the water outlet valve is fully opened will cause overload of the motor; If
the inlet valve is turned down to control the flow, cavitation will occur in the
self-priming pump. Both should be avoided.
2. Run
(1) The oil level of the
self-priming pump with suspension oil chamber must be kept at 1/3 and 2/3 of the
oil pointer.
(2) The mechanical seal shall not have any leakage. Otherwise,
replace the mechanical seal with a new one.
(3) Check whether the flow and
lift (inlet and outlet pressure) of the pump are stable and meet the
requirements of the working conditions, whether the current value in the ammeter
is stable and within the normal range allowed by the motor, whether the
self-priming pump unit has abnormal noise, whether the running noise and
vibration are excessive, and whether the temperature of the bearing is within
the normal range (the temperature rise of the bearing should generally not
exceed the ambient temperature by 35 ℃, but the high temperature of zui should
not exceed 75 ℃).
3. Shutdown
(1) Before shutdown, slowly close the water
outlet valve, close the vacuum gauge cock, cut off the power, and then close the
pressure gauge cock.
(2) For the self-priming pump running in series (less
used), the last stage pump shall be closed first when stopping. After stopping,
the outlet valve shall be closed, and then the * stage pump shall be
closed.
(3) When the ambient temperature of the pump installation location is
low, the liquid in the pump shall be discharged after shutdown to avoid freezing
the pump or pipeline system.
If the liquid level is higher than that of the
pump and water can flow into the pump body, we suggest that centrifugal pump be
used. If the liquid level is lower than that of the pump, all kinds of
self-priming pumps need to be selected
11/07/2022
Operating Instructions for Self priming Pump