Any kind of product has a service life, and the vacuum pump can't be avoided. In the process of use, various problems can't be avoided, and the vacuum pump needs to be repaired. Vacuum pump filter resistance and blockage is one of the two problems, always bothering consumers, the following yazhileide electromechanical technology to tell you the solution to this problem!
1、 Resistance loss
If we want to solve the problem, we must find the root of the problem. The same is true of the filter element resistance loss of vacuum pump. We must find out the cause of the resistance loss and what causes the filter element resistance loss. Only in this way can we find every method corresponding to each cause.
There are two main reasons for the resistance loss of vacuum pump filter element, one is the change of geometry. In this case, the filter element should be removed to see the degree of deformation. If it is slightly deformed, it can be slightly repaired and reused. If it is severely deformed, it should not be used any more, otherwise it will aggravate the damage of the vacuum pump.
The other reason is that high temperature oxidation and water droplet atomization make the filter element of Edwards vacuum pump have impurity particles and lead to filter element resistance loss. Some of them are left behind during cleaning. At this time, it is necessary to thoroughly clean the filter element, first use a brush or blower to get out the impurity particles, and then use the cleaning agent to clean up, no more impurities left.
The above are two ways to solve the resistance loss of vacuum pump filter element. I hope you can use and maintain it correctly and extend its service life as far as possible.
Maintenance of vacuum pump: filter element blocked
2、 Clogging
An effective way to solve the blockage is to install the vacuum pump exhaust filter element. When the vacuum pump filter element is working, it will filter some impurities in water or oil. After installing the vacuum pump exhaust filter element, it will absorb the impurities in water and oil. This can ensure the Edward vacuum pump to work in a clean environment and avoid the blockage of the vacuum pump.
In addition, in addition to the problem of blockage, the filter element of the vacuum pump also needs routine maintenance. The staff should listen carefully to the noise of the vacuum pump, check the impurities in the filter element of the vacuum pump, and check whether there are oil stains in the exhaust port. If there is any abnormal situation, the vacuum pump repairman should repair or replace the parts immediately.
The above is to tell you how to solve the problem of vacuum pump filter plugging, you must carefully observe its operation, to ensure normal work.
Related products:
No comments: