During the operation of
the pipeline, some factors may reduce the head. The following are the six
reasons.
1. Impeller passage blocked
The blockage of impeller flow passage
will affect the work done by the impeller, and the pressure at the outlet will
drop. This problem can be prevented by removing the pump body, removing foreign
matters, and installing a filter device at the pump inlet.
2. Internal
leakage occurs
The clearance between the rotating part and the stationary
part of the pump body is too large, which exceeds the design index, and internal
leakage will occur. The phenomenon is that the discharge pressure of the pump
decreases, such as the clearance between the impeller ring and the interstage
clearance of multistage pump. At this time, the corresponding inspection and
replacement of components should be carried out.
3. Cavitation at
inlet
When the inlet pressure of the pump is too low, lower than the
saturated vapor pressure of the pumping ring, cavitation will occur. The
solution is to check whether the inlet pipeline system is blocked, whether the
opening of the inlet valve is too small, or increase the liquid level of the
suction pool.
4. Speed decrease
The important factors for head reduction
are the outer diameter of the impeller and the speed of the pump. Under the same
conditions, the head is in direct proportion to the quadratic power of the
speed, so the speed has a great impact on the head. Some reasons reduce the
speed of the pump, which will affect the head. At this time, check the speed of
the pump. If the speed is not enough, find out the cause and eliminate it.
5.
The operating point is shifted to large flow and low lift
In most cases, the
interest energy has a continuous rural performance curve, and the flow increases
as the head decreases. In use, if there is some factor that causes the back
pressure of the pump to decrease, the working point of the pump will shift to
the point with large head and flow along with the device curve, which will cause
the head to decrease. This is mainly caused by the change of external factors,
and has nothing to do with the pump itself. It can be solved by increasing the
pump back pressure.
6. Motor reverse
Improper wiring results in the motor
steering contrary to the actual requirements of the pump. Normally, observe the
rotation direction of the pump when starting. If it reverses, exchange any two
wires of the terminal on the motor.
Why do pneumatic ball valves need stainless steel pipe fittings for connection?