Roots vacuum pump may have some minor faults in the process of use. Returning to the factory for maintenance will waste a lot of time and bring losses to the enterprise, which requires the manufacturer to disassemble and repair itself. How can we disassemble and assemble the equipment correctly? Let's get to know it.
1. Before the Roots vacuum pump is dismantled, the clearance of each part of the rotor is measured and recorded.
2. Avoid hammering as much as possible. The parts removed should not be bruised and kept properly.
3. Record in detail the reasons for replacement of parts and components that need to be replaced and their usage.
4. Before reassembling Roots vacuum pump, all parts must be cleaned and burrs repaired.
5. The "106" silicone rubber coating is used for the static sealing surface without gasket or seal ring. Vacuum coke grease should be applied to clean and sealed rubber seals. Sealing rings on relief valves of vacuum pumps with relief valves and flat surfaces shall not be coated with Renke grease.
6. Adjust the clearance of each part of the rotor according to the clearance list.
7. Leakage must be checked after all are installed.
8. Trial operation and necessary performance test should be carried out after reinstallation. It can not be installed and used until it is normal.
The disassembly and assembly of Roots vacuum pump should be carried out in strict accordance with the operation instructions. During the disassembly process, the data and steps should be carefully recorded. Leakage should be checked before reuse. Otherwise, the damage of the equipment will be deepened and the loss will be overwhelming.
No comments: