11/28/2019

Water ring vacuum pump suddenly shut down how to solve


Water ring vacuum pump can be widely used in the vacuum pump, etc., and use more stable, but in the use of equipment may arise suddenly stop running, if rule out conditions is a sudden power outage, so we need to check whether the equipment problems, this is not to the secondary to open, we should deal with the problem and then began to run, let's learn about the equipment suddenly shut down how to solve it.
1, the packing or seal wear, resulting in air leakage into the equipment, then need to check the packing or seal and according to the needs of the corresponding replacement, but also check whether the lubrication is normal.
2. Check whether the inlet pipeline is leaking. It is usually necessary to check the inlet line for air cavitation or air leakage.
3. Sometimes the impeller or pipeline may be blocked. It is necessary to check whether the pipeline is blocked by obstacles. If there is any blockage, it should be dealt with in time. If there is no blockage of the water ring vacuum pump, it needs to be dealt with again.
Water ring vacuum pump suddenly shut down how to solve
4. The immersion depth of the bottom valve or inlet pipe of the equipment is still not enough, so it needs to be immersed to the correct depth to continue normal operation.
5. It may be due to insufficient water absorption when pumping hot or volatile liquids. In this case, it is generally necessary to increase the suction head, if you do not know how to operate, you need to consult with the manufacturer or find a professional to deal with.
6. The suction range is too high, so please check whether the net pressure head is normal in case of this kind of problem. It may be that the inlet line is too small or too long, which will cause wear.

Oxygen Compressor Air Compressor
Best vacuum pump manufacturer
Vacuum pump technology in tool heat treatment
Vacuum system in thin film solar cell

No comments:

Post a Comment